Description
Dräger Tubes For Short Term Measurements: Benzene 0.25/a
Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Benzene 0.25/a).
The tubes come in a pack of 10 tubes and have a shelf life of 2 years.
Application Range:
Standard Measuring Range: | 0.25 to 2 ppm /2 to 10 ppm |
Number of Strokes n: | 5 |
Time for Measurement: | 5 |
Standard Deviation: | ± 15 % |
Colour Change: | light grey to dark grey to black |
Ambient Operating Conditions:
Temperature: | 0 to 40 °C |
Absolute Humidity | < 40 mg H2O / L |
Reaction Principle:
Benzene + Alu+ ~> dark grey to black reaction product
Cross Sensitivity:
Up to a concentration of approx. 40 ppm (n=5) and 200 ppm (n=1), toluene, xylene and ethyl benzole are kept in the pre-layer where they cause a brown discolouration. 800 ppm n-Oktane (n=5) and 4000 ppm n-Octane (n=1) do not cause any discoluration in the indicating layer..