Dräger Tube -Ethyl Acetate 200/a

DrägerSKU: CH20201

Price:
Sale price£83.61

Description

Dräger Tubes For Short Term Measurements: Ethyl Acetate 200/a

Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Ethyl Acetate 200/a).

The tubes come in a pack of 10 tubes and have a shelf life of 2 years.

Part no Dräger Tube Substance Measurement Range
CH20201 Ethyl Acetate 200/a Acrylonitrile 25 to 250 ppm
i-Amyl Acetate 200 to 1000 ppm
n-Amyl Acetate 200 to 1000 ppm
n-Butyl Acetate 200 to 3000 ppm
Ethyl Acetate 200 to 9000 ppm
Isoamyl Alcohol Qualitative
Iso-Propyl Acetate 200 to 3000 ppm
Methyl Acetate 200 to 3000 ppm
2,4-Pentanedione Qualitative

Application Range:

Standard Measuring Range: 200 to 3,000 ppm
Number of Strokes n: 20
Time for Measurement: approx. 5 min
Standard Deviation: ± 15 to 20 %
Colour Change: orange to green brown

Ambient Operating Conditions:

Temperature: 17 to 40 °C
Absolute Humidity 3 to 15 mg H2O / L

Reaction Principle:

CH3COOC2H5 + CrVI ~> CrIII + various oxidation products

Cross Sensitivity:

Many petroleum hydrocarbons, alcohols, aromatics and esters are indicated, but with different sensitivities. It is impossible to differentiate between them..

For more information on Dräger-Tubes click the image below.

To view our range of Dräger pumps please click below.

You may also like