Dräger Tubes For Short Term Measurements: Aniline (0.5/a)
Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Aniline (0.5/a)
The tubes come in a pack of 5 tubes and have a shelf life of 2 years.
Part no | Dräger Tube | Substance | Measurement Range |
6733171 | Aniline 0.5/a | Aniline | 0.5 to 10 ppm |
N,N-Dimethylaniline | 0.5 to 10 ppm |
Application Range:
Standard Measuring Range: | 0.5 to 10 ppm |
Number of Strokes n: | 20 |
Time for Measurement: | approx. 4 min. |
Standard Deviation: | ± 15 to 20 % |
Colour Change: | pale yellow to pale green. |
Ambient Operating Conditions:
Temperature: | 15 to 30°C |
Absolute Humidity | 7 to 12 mg H2O/L |
Reaction Principle:
C6H5NH2 + CrVI ~> CrIII + various oxidation products
Cross Sensitivity:
When methyl aniline and aniline are present at the same time, it is impossible to measure only the aniline concentration. Ethers, ketones, esters, aromatics and benzines are indicated as well but with different sensitivities.