Description
Dräger Tubes For Short Term Measurements: Thioether
Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Thioether).
The tubes come in a pack of 10 tubes and have a shelf life of 2 years.
Application Range:
Standard Measuring Range: | 1 mg/m3 is the minimum detectable concentration in form of a ring. |
Number of Strokes n: | 8 |
Time for Measurement: | approx. 1.5 min |
Standard Deviation: | ± 50 % |
Colour Change: | yellow to orange |
Ambient Operating Conditions:
Temperature: | 0 to 40 °C |
Absolute Humidity | < 50 mg H2O / L |
Reaction Principle:
R'-S-R + AuCI3 + Chloramide ~> orange reaction product
Cross Sensitivity:
Various thioethers are indicated, but it is impossible to differentiate between them..
For more information on Dräger-Tubes click the image below.
To view our range of Dräger pumps please click below.