Description
Midas® S2 Sensor Cartridges Carbon Dioxide (CO2) 1.05-12 ppm P/N: MIDAS S2-E-CO2
Selectable gases | Carbon Dioxide (CO2) |
Cartridge Part Number | MIDAS S2-E-CO2 2-year extended warranty |
Sensor Technology | Electrochemical sensor |
Measuring Range | CO2 0 – 2%vol |
Default Alarm 1 | CO2 0.25%vol |
Default Alarm 2 | CO2 0.5%vol |
LDL, LAL | CO2 0.15%vol |
Resolution | CO2 0.05%vol |
Accuracy | ≤ ± 10% of measured value |
Response Time t62.5 | Typical 25 seconds |
Sensor Cartridge Life Expectancy (Expiration Period) |
24 months under typical application conditions Extendable for 1 year through calibration after 24 months |
Operating Temperature Effect of Temperature Sensitivity |
0°C to +40°C (32°F to 104°F) ≤ ± 20% of measured value at 20°C |
Operating Humidity | 10 to 90% non-condensing |
Operating Pressure | 90 – 110kPa |
Calibration Gas | CO2 1%vol |
Warm Up Time | < 20 minutes |
Storage Temperature | +5°C to +25°C (+41°F to +77°F) |