Midas® S2 Sensor Cartridges Methylpropane (C4H10) 3-100% LEL P/N: MIDAS S2-E-LEB

Selectable gases Butane (C4H10)
Cartridge Part Number MIDAS S2-E-LEB 2-year extended warranty
Sensor Technology Catalytic bead sensor
Measuring Range C4H10 0 - 100%LEL
Default Alarm 1 C4H10 10%LEL
Default Alarm 2 C4H10 20%LEL
LDL, LAL C4H10 3%LEL
Resolution C4H10 0.5%LEL
Accuracy ≤ ± 5% of measured value
Response Time t62.5 Typical 16 seconds
Sensor Cartridge Life Expectancy
(Expiration Period)
60 months under typical application conditions
Operating Temperature
Effect of Temperature Sensitivity
0°C to +40°C (32°F to 104°F)
≤ ± 10% of measured value at 20°C
Operating Humidity 0 to 99% non-condensing
Operating Pressure 90 – 110kPa
Calibration Gas C4H10 50%LEL
Warm Up Time < 30 minutes
Storage Temperature +5°C to +25°C (+41°F to +77°F)